5985-00-481-8113 WAVEGUIDE ASSEMBLY Index 5910-00-481-8115 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5985-00-481-8114

Federal Supply Class:
5985

National Item Identification Number:
004818114

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
11457566544FRONTGRADE TECHNOLOGIES INC.
11457580006LITTON SYSTEMS INC AIRTRON DIV
TS5749506351MICROWAVE ENGINEERING CORPORATION
V000660-05012436BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES
FLANGE DEPTH0.298 INCHES MINIMUM ALL FLANGES AND 0.328 INCHES MAXIMUM ALL FLANGES
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES
FLANGE INSIDE HEIGHT0.394 INCHES MINIMUM ALL FLANGES
FLANGE INSIDE WIDTH0.705 INCHES MINIMUM ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECOVER TYPE ALL FLANGES
FLANGE OUTSIDE HEIGHT1.298 INCHES MINIMUM ALL FLANGES AND 1.328 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH1.298 INCHES MINIMUM ALL FLANGES AND 1.328 INCHES MAXIMUM ALL FLANGES
FLEXIBILITYFLEXIBLE SINGLE TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AN RELATED EQUIPMENT
INSERTION LOSS IN DECIBELS0.50
MATERIALCOPPER ALLOY ALL TUBING SEGMENT AND FLANGE
PRECIOUS MATERIAL AND LOCATIONEXTERNAL SURFACES SILVER
PRECIOUS MATERIALSILVER
TUBING WALL CONSTRUCTION STYLECORRUGATED SINGLE TUBING SEGMENT
VOLTAGE STANDING WAVE RATIO1.35
WAVEGUIDE INSIDE HEIGHT0.3085 INCHES MINIMUM AND 0.3135 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.6195 INCHES MINIMUM AND 0.6245 INCHES MAXIMUM
WAVEGUIDE LENGTH19.080 INCHES MINIMUM AND 19.160 INCHES MAXIMUM
WAVEGUIDE CENTER TO CENTER DISTANCE4.320 INCHES MINIMUM AND 4.400 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM
STYLE DESIGNATOROFFSET BEND TYPE
SURFACE TREATMENTSILVER SINGLE TUBING SEGMENT OUTSIDE SURFACES AND RUBBER SINGLE TUBING SEGMENT OUTSIDE SURFACES
SURFACE TREATMENTSILVER ALL FLANGE OUTSIDE SURFACES AND PAINT ALL FLANGE OUTSIDE SURFACES


Click here to Register for Free 30-day Trial