CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE DEPTH | 0.298 INCHES MINIMUM ALL FLANGES AND 0.328 INCHES MAXIMUM ALL FLANGES |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM ALL FLANGES AND 0.396 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM ALL FLANGES AND 0.707 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | COVER TYPE ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM ALL FLANGES AND 1.328 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM ALL FLANGES AND 1.328 INCHES MAXIMUM ALL FLANGES |
FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
INSERTION LOSS IN DECIBELS | 0.40 |
MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
MATERIAL | RUBBER SYNTHETIC SINGLE TUBING JACKET |
PRECIOUS MATERIAL AND LOCATION | ALL SURFACES SILVER |
PRECIOUS MATERIAL | SILVER |
TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
VOLTAGE STANDING WAVE RATIO | 1.25 |
WAVEGUIDE INSIDE HEIGHT | 0.3085 INCHES MINIMUM AND 0.3135 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.6195 INCHES MINIMUM AND 0.6245 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 26.900 INCHES MINIMUM AND 27.100 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
STYLE DESIGNATOR | STRAIGHT TYPE |
SURFACE TREATMENT | ENAMEL ALL FLANGE OUTSIDE SURFACES |
SURFACE TREATMENT | SILVER ALL TUBING SEGMENT AND FLANGE ALL SURFACES |