| INSTALLATION DESIGN | PANEL |
| PANEL FOR WHICH DESIGNED | MAGNETIC |
| INDICATOR TYPE | DIAL W/POINTER |
| SCALE MARKING | SCALE MEASURES FLUID RESISTIVITY |
| ACCURACY IN PERCENT | -10.0 TO 10.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES |
| SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR ALL RANGES |
| SCALE DIVISION QUANTITY | 40 SINGLE INDICATOR ALL RANGES |
| POINTER COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR ALL RANGES |
| CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
| CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
| OPERATING VOLTAGE RATING IN VOLTS | 115.0 AC NOMINAL |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL |
| STYLE DESIGNATOR | RECTANGULAR FLUSH MTG |
| METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.620 INCHES NOMINAL |
| METER DEPTH BEHIND MOUNTING FLANGE | 0.750 INCHES NOMINAL |
| OVERALL HEIGHT | 4.000 INCHES NOMINAL |
| OVERALL LENGTH | 1.250 INCHES NOMINAL |
| OVERALL WIDTH | 5.000 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
| MOUNTING STUD DIAMETER | 0.138 INCHES NOMINAL |
| MOUNTING STUD LENGTH | 0.500 INCHES NOMINAL |
| MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.990 INCHES MINIMUM AND |
| 4.010 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.490 INCHES MINIMUM AND |
| 3.510 INCHES MAXIMUM |
| NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |