National Stock Number: 6625-00-542-1331
Federal Supply Class: 6625
National Item Identification Number: 005421331
Description: TEST SET,INSULATION BREAKDOWN
Detail: A TEST SET PRIMARILY DESIGNED TO DETECT AND INDICATE INSULATION BREAKDOWN IN ELECTRIC MOTORS, TRANSFORMERS, AND THE LIKE, AT SPECIFIC TEST VOLTAGES. SEE ALSO TEST SET, ARMATURE; AND OHMMETER.
|
Manufacturer Information:
22001M0DEL1 | 07239 | AVO INTL | ANGSM6 | 80058 | JOINT ELECTRONICS TYPE DESIGNATION SYSTEM | SM-D-349276 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR |
|
Techincal Specification:
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL | FREQUENCY RATING | 60.0 HERTZ NOMINAL | INSTALLATION DESIGN | PORTABLE | LEAKAGE INDICATOR TYPE | METER | OUTPUT CURRENT TYPE | DC | OUTPUT VOLTAGE RATING | 400.000 VOLTS MINIMUM AND 500.000 VOLTS MAXIMUM | OVERALL HEIGHT | 19.500 INCHES NOMINAL | OVERALL LENGTH | 20.000 INCHES NOMINAL | OVERALL WIDTH | 13.500 INCHES NOMINAL | METER QUANTITY | 2 | METER TYPE | AMMETER AND VOLTMETER | PHASE | SINGLE | SCALE RANGE | +0.0 TO 40.0 KILOVOLTS AND +0.0 TO 50.0 MICROAMPS | SPECIAL FEATURES | CIRCUIT BREAKER OVERLOAD PROTECTIION W/SPARK GAP AND NEON LAMPS TO PROTECT METER;AMMETERS HAS MULTIPLIERS OF 1,10,100 AND 1000 TO INCREASE RANGE TO50,000 UA,VOLTAGE DOUBLER TYPE CIRCUITW/HIGH VOLTAGE SECTION IMMERSED IN OIL;EITHER PLUS OR MINUS OUTPUT TERMINAL MAY BE CONNECTED TO GUARD TO FORM/COLDGUARD CIRCUIT;INCL 1 TEST SET NO. TS-928/U,1 CABLE ASSEMBLY,POWER,ELECTRICAL,50 FT LG AND 1 LEAD ELECTRICAL 5 FT LG |
|
|