INSTALLATION DESIGN | PANEL |
INDICATOR TYPE | DIAL W/POINTER |
MEASUREMENT RANGE | 0.0 TO 5.0 KILOVOLTS, DC SINGLE INDICATOR SINGLE RANGE |
ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR SINGLE RANGE |
SCALE DIVISION QUANTITY | 10 SINGLE INDICATOR SINGLE RANGE |
POINTER COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER LUG AND |
| 2 THREADED STUD |
SENSITIVITY RATING | 1.0 MILLIAMPERES |
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 3000.0 |
POWER SOURCE | EXTERNAL |
CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
STYLE DESIGNATOR | ROUND FLUSH MTG |
METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.800 INCHES MAXIMUM |
METER DEPTH BEHIND MOUNTING FLANGE | 1.660 INCHES MAXIMUM |
OVERALL DIAMETER | 3.510 INCHES MAXIMUM |
OVERALL LENGTH | 2.850 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 3 SCREW AND |
| 3 UNTHREADED HOLE |
MOUNTING HOLE DIAMETER | 0.143 INCHES MINIMUM AND |
| 0.157 INCHES MAXIMUM |
MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
MOUNTING BOLT CIRCLE DIAMETER | 3.160 INCHES NOMINAL |
MATERIAL | STEEL |
SURFACE TREATMENT | ENAMEL |
NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
FURNISHED ITEMS AND QUANTITY | NUT 5; LOCKWASHER 5; SEAL 1 |
SPECIAL MARKINGS | ORANGE BAND MARKED ACC.,UNDER SCALE FROM 0.8 TO 2.2 KV; YELLOW BAND MARKED SOLE,ABOVE SCALE FROM 1 TO 3.4 KV; GREEN BAND MARKED CATHODE,ABOVE SCALE FROM 1 TO 3.4 KV; GREEN BAND MARKED CATHODE,ABOVE SCALE FROM 2.3 TO 4 KV |
FEATURES PROVIDED | ZERO ADJUSTER |
SPECIAL FEATURES | ON BACK,SEALED DO NOT OPEN; RUGGEDIZED |
SPECIAL TEST FEATURES | CONFORMS TO MIL-M-10304/11,TYPE MR36A001DCKVR |
SUPPLEMENTARY FEATURES | 1 MA POWER CONSUMPTION |
FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |