3110-00-485-7597 BEARING,BALL,ANNULAR Index 3120-00-485-7603 BEARING,SLEEVE

National Stock Number:
5990-00-485-7600

Federal Supply Class:
5990

National Item Identification Number:
004857600

Description:
SYNCHRO,TRANSMITTER

Detail:
A SYNCHRO CONSISTING OF A STATOR AND ROTOR INDUCTIVELY COUPLED. THE ELECTRICAL OUTPUT OF THE STATOR INTO A RECEIVER SYNCHRO, A CONTROL TRANSFORMER OR DIFFERENTIAL SYNCHRO IS DEPENDENT UPON THE POSITION OF ITS ROTOR. DOES NOT INCLUDE VARIABLE RESISTORS, GONIOMETERS, VARIABLE TRANSFORMERS, OR ITEMS WITH DIALS.


Manufacturer Information:
11CX310G21E06989API HAROWE INC DBA API MOTION DIV API MOTION/PMI/API HAROWE
7500201620189944ELBITAMERICA, INC.


Techincal Specification:
ELECTRICAL ERROR ANGULAR RANGE IN MINUTES-7.0 TO 7.0
ACTUATOR FRICTION TORQUE AT PLUS 25 DEG CELSIUS0.04 INCH-OUNCES MAXIMUM
BODY DIAMETER0.7530 INCHES MAXIMUM
BODY SIZE8
BODY STYLESTANDARD ROUND, ROTATABLE HOUSING
FLANGE DIAMETER1.0600 INCHES MINIMUM AND 1.0620 INCHES MAXIMUM
FLANGE THICKNESS0.0700 INCHES MINIMUM AND 0.0750 INCHES MAXIMUM
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZ400.0 NOMINAL
OVERALL LENGTH1.6680 INCHES MINIMUM AND 1.6980 INCHES MAXIMUM
MAXIMUM FUNDAMENTAL NULL VOLTAGE IN MILLIVOLTS PER VOLT20.00 OUTPUT
MAXIMUM TEMP RISE20.0 CELSIUS
MAXIMUM TOTAL NULL VOLTAGE OUTPUT IN MILLIVOLTS PER VOLT30.00
MOUNTING SURFACE TO TERMINAL END DISTANCE1.0380 INCHES NOMINAL
PHASE SHIFT ANGLE IN DEG7.000 INPUT TO OUTPUT MINIMUM AND 10.000 INPUT TO OUTPUT MAXIMUM
ROTOR INPUT CURRENT RATING153.0 MILLIAMPERES NOMINAL
ROTOR INPUT ELECTRICAL POWER RATING700.0 MILLIWATTS NOMINAL
ROTOR INPUT VOLTAGE RATING IN VOLTS26.0 NOMINAL
SHAFT DIAMETER0.1243 INCHES MINIMUM AND 0.1248 INCHES MAXIMUM SINGLE SHAFT
SHAFT LENGTH0.3640 INCHES MINIMUM AND 0.3880 INCHES MAXIMUM SINGLE SHAFT
SHAFT SLOT WIDTH0.0150 INCHES MINIMUM AND 0.0250 INCHES MAXIMUM SINGLE SHAFT
SHAFT TYPEROUND, SLOTTED SINGLE SHAFT
SHAFT SLOT DEPTH0.0250 INCHES MINIMUM AND 0.0350 INCHES MAXIMUM SINGLE SHAFT
SHOULDER DIAMETER0.7495 INCHES MINIMUM AND 0.7500 INCHES MAXIMUM
ZRO IMPEDANCE ANGLE IN DEG77.50 MINIMUM AND 80.50 MAXIMUM
ZRO IMPEDANCE MAGNITUDE IN OHMS170.00 MINIMUM AND 215.00 MAXIMUM
ZSS IMPEDANCE ANGLE IN DEG9.00 MINIMUM AND 15.00 MAXIMUM
ZSS IMPEDANCE MAGNITUDE IN OHMS11.00 MINIMUM AND 15.00 MAXIMUM
TERMINAL LOCATIONREAR
TERMINAL TYPE AND QUANTITY5 WIRE LEAD
TRANSFORMATION RATIO0.454 ROTOR TO STATOR NOMINAL