BEND ANGLE IN DEG | 90.0 FIRST BEND E-PLANE |
BEND ANGLE IN DEG | 90.0 SECOND BEND E-PLANE |
BEND ANGLE IN DEG | 90.0 THIRD BEND H-PLANE |
CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM SECOND FLANGE |
FLANGE DEPTH | 0.422 INCHES MINIMUM AND 0.453 INCHES MAXIMUM SECOND FLANGE |
FLANGE DEPTH | 0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM FIRST FLANGE |
FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM AND 1.006 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE HEIGHT | 1.570 INCHES MINIMUM AND 1.610 INCHES MAXIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 2.070 INCHES MINIMUM AND 2.110 INCHES MAXIMUM FIRST FLANGE |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CONTACT TYPE FIRST FLANGE |
FLANGE STYLE | COVER TYPE SECOND FLANGE |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
INSERTION LOSS IN DECIBELS | 0.12 |
MATERIAL | ALUMINUM ALLOY ALL FLANGE |
MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT |
MAXIMUM OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAGE |
SPECIAL FEATURES | FOUR ANGLE BRACKETS,TWO 2.500 IN. FROM FIRST END AND THE OTHER TWO ON THE CENTER SECTION 3.000 IN. FROM ONE END,ALL BRACKETS HAVE 0.196 IN. W. BY 0.312 IN. LG. SLOTS,TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED |
VOLTAGE STANDING WAVE RATIO | 1.11 |
WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
SURFACE TREATMENT | OXIDE FILM ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
SURFACE TREATMENT | OXIDE FILM SINGLE TUBING SEGMENT INSIDE SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |