5985-00-545-4853 WAVEGUIDE ASSEMBLY Index 1285-00-545-4856 CHECK ARM ASSEMBLY

National Stock Number:
5985-00-545-4854

Federal Supply Class:
5985

National Item Identification Number:
005454854

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
283722610001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BEND ANGLE IN DEG45.0 SECOND BEND E-PLANE
BEND ANGLE IN DEG45.0 THIRD BEND E-PLANE
BEND ANGLE IN DEG90.0 FIRST BEND E-PLANE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY8 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE CONNECTING HOLE DIAMETER0.167 INCHES MINIMUM AND 0.171 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM ALL FLANGES
FLANGE DEPTH0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.730 INCHES MINIMUM AND 1.770 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH2.480 INCHES MINIMUM AND 2.520 INCHES MAXIMUM ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECONTACT TYPE ALL FLANGES
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
INSERTION LOSS IN DECIBELS0.15
MATERIALALUMINUM ALLOY ALL FLANGE
MATERIALALUMINUM ALLOY SINGLE TUBING SEGMENT
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
SPECIAL FEATURESTUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED
VOLTAGE STANDING WAVE RATIO1.10
WAVEGUIDE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM
WAVEGUIDE LONGER OFFSET DISTANCE3.333 FEET NOMINAL
WAVEGUIDE OFFSET DISTANCE0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM
STYLE DESIGNATORBEND TYPE
SURFACE TREATMENTOXIDE FILM ALL FLANGE OUTSIDE SURFACES
SURFACE TREATMENTOXIDE FILM SINGLE TUBING SEGMENT INSIDE SURFACES
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT