5962-00-503-5382 MICROCIRCUIT,LINEAR Index 5950-00-503-5396 TRANSFORMER,RADIO FREQUENCY

National Stock Number:
5985-00-503-5389

Federal Supply Class:
5985

National Item Identification Number:
005035389

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
605884-10317480GUIDE MICROWAVE INC
673121-10305AU1A T WAVEGUIDE COMPONENTS
673121-1035Z167ASTRO MICROWAVE INC
673121-10398897LOCKHEED MARTIN CORP


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE DIAMETER1.406 INCHES MINIMUM FIRST FLANGE AND 1.437 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.396 INCHES MINIMUM FIRST FLANGE AND 0.404 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM SECOND FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE WIDTH0.896 INCHES MINIMUM FIRST FLANGE AND 0.904 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYRIGID ALL TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
MATERIALALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
III STYLE DESIGNATORDOUBLE BEND TYPE
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM OPERATING PRESSURE45.0 POUNDS PER SQUARE INCH GAGE
NOMINAL THREAD SIZE0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
VOLTAGE STANDING WAVE RATIO1.08
WAVEGUIDE CENTER TO CENTER DISTANCE8.870 INCHES MINIMUM AND 8.930 INCHES MAXIMUM
WAVEGUIDE HEIGHT2.370 INCHES MINIMUM AND 2.430 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM
SURFACE TREATMENTCHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
THREAD CLASS2B FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THREAD QUANTITY PER INCH32 FIRST FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNC FIRST FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT