CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.199 INCHES MINIMUM AND 0.203 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE HEIGHT | 1.002 INCHES MINIMUM AND 1.005 INCHES MAXIMUM ALL FLANGES |
FLANGE DEPTH | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE WIDTH | 2.002 INCHES MINIMUM AND 2.005 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | COVER TYPE ALL FLANGES |
FLANGE OUTSIDE DIAMETER | 3.610 INCHES MINIMUM AND 3.640 INCHES MAXIMUM ALL FLANGES |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
WAVEGUIDE OUTSIDE HEIGHT | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM |
WAVEGUIDE INSIDE HEIGHT | 0.867 INCHES MINIMUM AND 0.877 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 1.867 INCHES MINIMUM AND 1.877 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 7.375 FEET MINIMUM AND 7.625 FEET MAXIMUM |
STYLE DESIGNATOR | STRAIGHT TYPE |
SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |