CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE CONNECTING HOLE DIAMETER | 0.140 INCHES MINIMUM AND 0.144 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE QUANTITY | 2 |
FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
INSERTION LOSS IN DECIBELS | 0.10 |
MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
MAXIMUM OPERATING PRESSURE | 20.0 POUNDS PER SQUARE INCH GAGE |
PRECIOUS MATERIAL AND LOCATION | INTERNAL TUBING SEGMENT SURFACES AND OVERALL FLANGE SURFACES SILVER |
PRECIOUS MATERIAL | SILVER |
STYLE DESIGNATOR | BEND TYPE |
VOLTAGE STANDING WAVE RATIO | 1.05 |
WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
WAVEGUIDE LONGER OFFSET DISTANCE | 2.125 INCHES NOMINAL |
WAVEGUIDE OFFSET DISTANCE | 2.000 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |