BODY HEIGHT | 2.750 INCHES MAXIMUM |
BODY LENGTH | 6.360 INCHES NOMINAL |
BODY WIDTH | 4.600 INCHES NOMINAL |
FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
MAXIMUM OPERATING TEMP | 95.0 CELSIUS |
MOUNTING FACILITY QUANTITY | 12 SINGLE GROUP |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 2.45 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING CURRENT | 13.9 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING CURRENT | 816.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING VOLTAGE | 130.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING POWER RATING | 3.1 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 9.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING VOLTAGE | 9.70 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |