5310-00-494-7459 WASHER,FLAT Index 5320-00-494-7468 RIVET,SOLID

National Stock Number:
5950-00-494-7464

Federal Supply Class:
5950

National Item Identification Number:
004947464

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
100201508779SIGNAL TRANSFORMER CO INC
100201510581STANDEX ELECTRONICS INC.
100201595750AIRCO REPUBLIC ELECTRONICS, INC.


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING45.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT3.500 INCHES NOMINAL
OVERALL LENGTH3.750 INCHES NOMINAL
OVERALL WIDTH2.750 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE SINGLE GROUP AND SLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.190 INCHES NOMINAL SINGLE GROUP
WINDING FUNCTION AND QUANTITY2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT2.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT250.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE10.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE10.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY10 TAB, SOLDER LUG