2840-00-433-7190 TIE BOLT,TURBINE Index 5930-00-433-7194 SWITCH,ROTARY

National Stock Number:
5950-00-433-7192

Federal Supply Class:
5950

National Item Identification Number:
004337192

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1018207518876U S ARMY AVIATION AND MISSILE COMMAND
1616943B150RAYTHEON COMPANY
522113483PRECISION ELECTRONICS, INC
16169449956RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT2.120 INCHES MAXIMUM
BODY LENGTH3.880 INCHES MAXIMUM
BODY WIDTH2.880 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.940 INCHES MINIMUM AND 2.060 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SIX PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP170.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL TYPE AND QUANTITY14 TURRET
THREAD SERIES DESIGNATORUNC SINGLE GROUP
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA AND DELTA-WYE
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT18.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT4.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE11.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE14.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING SHIELDING METHODGROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT