TERMINAL TYPE AND QUANTITY | 2 STANDOFF, THREADED STUD AND |
| 3 THREADED STUD |
WINDING OPERATING VOLTAGE | 105.00 AC VOLTS NOMINAL AND |
| 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| 24.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
FREQUENCY RATING | 50.0 HERTZ NOMINAL OR |
| 60.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 1 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED STUD SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 3 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | HERMETICALLY SEALED |
BODY LENGTH | 5.500 INCHES MINIMUM AND |
| 5.625 INCHES MAXIMUM |
BODY HEIGHT | 6.687 INCHES MINIMUM AND |
| 6.875 INCHES MAXIMUM |
BODY WIDTH | 5.125 INCHES MINIMUM AND |
| 5.250 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |