5945-00-549-6347 RELAY,ELECTROMAGNETIC Index 5305-00-549-6349 SCREW,CAP

National Stock Number:
5945-00-549-6348

Federal Supply Class:
5945

National Item Identification Number:
005496348

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
36A34795AA00230222GENERAL ELECTRIC CO SPEED VARIATOR PRODUCTS OPERATION
401-1401-0013499ROCKWELL COLLINS, INC.
405-0645-00913499ROCKWELL COLLINS, INC.
5945005496348A00AME.C.A ETABLISSEMENT CENTRAL DESAPPROVISIONNEMENTS DES FORCES ARMEE
5945PL10660389009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
5945PL20749999009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24192-D196906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24192D101359TRIUMPH THERMAL SYSTEMS - MARYLAND, INC.
MS24192D160144UNIFAB INDUSTRIES INC
MS34192D1ASG96906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
TIP0000697403CECOM LR CENTER


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CASE MATERIALMETAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.469 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE23.256 CUBIC INCHES
ENVIRONMENTAL PROTECTIONSHOCK RESISTANT
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC AND 25.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC AND 25.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT2.750 INCHES MAXIMUM
OVERALL LENGTH3.062 INCHES MAXIMUM
OVERALL WIDTH2.750 INCHES MAXIMUM
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIFICATION/STANDARD DATA96906-MS24192 GOVERNMENT STANDARD
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
WINDING DC RESISTANCE RATING92.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY8 THREADED STUD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.01 SECONDS MAXIMUM FIXED RELEASE TIME
TIME DELAY0.02 SECONDS MAXIMUM FIXED OPERATE TIME
UNTHREADED MOUNTING HOLE DIAMETER0.219 INCHES NOMINAL SINGLE MOUNTING FACILITY