5999-00-503-8028 CONTACT ASSEMBLY,ELECTRICAL Index 5962-00-503-8031 MICROCIRCUIT,LINEAR

National Stock Number:
5945-00-503-8030

Federal Supply Class:
5945

National Item Identification Number:
005038030

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
1422158880MEGGITT (NEW HAMPSHIRE), INC


Techincal Specification:
DUTY TYPECONTINUOUS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
ENVIRONMENTAL PROTECTIONHERMETIC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE3.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS28.0 DC
OVERALL HEIGHT1.710 INCHES NOMINAL
OVERALL LENGTH1.320 INCHES NOMINAL
OVERALL WIDTH0.960 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY3 THREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNTRIANGLE SINGLE MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE20.0 MILLIAMPERES DC SINGLE WINDING
NOMINAL THREAD SIZE0.112 INCHES SINGLE MOUNTING FACILITY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
WINDING DC RESISTANCE RATING450.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
THREAD CLASS2B SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATORUNC SINGLE MOUNTING FACILITY


Click here to Register for Free 30-day Trial