NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND |
| 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 230.0 AC AND |
| 230.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 30.0 AMPERES AC AND |
| 750.0 MILLIAMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 2 |
WINDING QUANTITY | 2 |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
TERMINAL TYPE AND QUANTITY | 12 PIN ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
OVERALL LENGTH | 10.375 INCHES NOMINAL |
OVERALL WIDTH | 8.875 INCHES NOMINAL |
OVERALL HEIGHT | 4.125 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
FEATURES PROVIDED | LATCHING CONTACTS |