5945-00-465-8170 RELAY,ELECTROMAGNETIC Index 5910-00-465-8172 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5945-00-465-8171

Federal Supply Class:
5945

National Item Identification Number:
004658171

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
1201257-01256232LOCKHEED MARTIN CORPORATION
5945PL13685949009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
M5757/13-01281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M5757/13-10581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-5757/1381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-5757/1381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.067 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.130 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE0.866 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE100.0 MILLIAMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE750.0 MILLIAMPERES DC INDUCTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT1.491 INCHES MAXIMUM
OVERALL LENGTH1.453 INCHES MAXIMUM
OVERALL WIDTH0.400 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNDIAGONAL SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH0.110 INCHES NOMINAL SINGLE MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE40.0 MILLIAMPERES DC SINGLE WINDING
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIFICATION/STANDARD DATA81349-MIL-R-5757/13 GOVERNMENT SPECIFICATION
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
WINDING DC RESISTANCE RATING90.0 OHMS MINIMUM AND 110.0 OHMS MAXIMUM SINGLE WINDING
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY8 WIRE HOOK ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.01 SECONDS MAXIMUM FIXED RELEASE TIME
TIME DELAY0.015 SECONDS MAXIMUM FIXED OPERATE TIME