DUTY TYPE | CONTINUOUSCONTINUOUS |
ARC QUENCHING METHOD | AIRAIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL FIRST MOUNTING FACILITY2.125 INCHES NOMINAL FIRST MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SECOND MOUNTING FACILITY2.125 INCHES NOMINAL SECOND MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL SECOND MOUNTING FACILITY1.000 INCHES NOMINAL SECOND MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL FIRST MOUNTING FACILITY1.000 INCHES NOMINAL FIRST MOUNTING FACILITY |
COIL QUANTITY | 11 |
CUBIC MEASURE | 10.562 CUBIC INCHES10.562 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETICHERMETIC |
FEATURES PROVIDED | COIL VOLTAGE SUPPRESSIONCOIL VOLTAGE SUPPRESSION |
FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
FREQUENCY IN HERTZ | 400.0 NOMINAL400.0 NOMINAL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC AND 6.0 AMPERES AC AND 6.0 AMPERES DC MOTOR LOAD6.0 AMPERES DC MOTOR LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 115.0 AC AND 28.0 DC28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES AC AND 10.0 AMPERES DC INDUCTIVE LOAD10.0 AMPERES DC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD10.0 AMPERES DC RESISTIVE LOAD |
OVERALL HEIGHT | 2.600 INCHES MAXIMUM2.600 INCHES MAXIMUM |
OVERALL LENGTH | 2.500 INCHES MAXIMUM2.500 INCHES MAXIMUM |
OVERALL WIDTH | 1.625 INCHES MAXIMUM1.625 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITYRECTANGULAR FIRST MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITYRECTANGULAR SECOND MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE FIRST MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SECOND MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERALGENERAL |
SPECIFICATION/STANDARD DATA | 96906-MS24149 GOVERNMENT STANDARD96906-MS24149 GOVERNMENT STANDARD |
WINDING QUANTITY | 11 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS8 SCREW ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL SECOND MOUNTING FACILITY0.173 INCHES NOMINAL SECOND MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL FIRST MOUNTING FACILITY0.173 INCHES NOMINAL FIRST MOUNTING FACILITY |