5970-00-501-0834 INSULATOR,STRAIN Index 5945-00-501-0837 RELAY,ROTARY

National Stock Number:
5930-00-501-0836

Federal Supply Class:
5930

National Item Identification Number:
005010836

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
3103-4-2114604HONEYWELL INTERNATIONAL INC.
578T170A18597896HONEYWELL INTERNATIONAL INC.
S70-0006-00114304L3HARRIS TECHNOLOGIES, INC.
MILS24236-181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M24236/1-00781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M507N170A18597896HONEYWELL INTERNATIONAL INC.


Techincal Specification:
BODY DIAMETER0.610 INCHES MINIMUM AND 0.630 INCHES MAXIMUM
BODY HEIGHT0.367 INCHES MINIMUM AND 0.390 INCHES MAXIMUM
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE
CONTACT LOAD CURRENT RATING2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE
CONTACT STIMULUS RATING180.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 190.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 165.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 175.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 15.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT ALTITUDE THIRD VOLTAGE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.928 INCHES MINIMUM
FEATURES PROVIDEDHERMETICALLY SEALED CASE
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
OVERALL HEIGHT0.627 INCHES MINIMUM AND 0.650 INCHES MAXIMUM
OVERALL LENGTH1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM
OVERALL WIDTH0.680 INCHES NOMINAL
MEDIA FOR WHICH DESIGNEDGAS
MOUNTING FACILITY PATTERNTWO POSITION IN-LINE
MOUNTING METHODBRACKET
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
OPERATING TEMP RATING-65.0 FAHRENHEIT MINIMUM AND 500.0 FAHRENHEIT MAXIMUM
STYLE DESIGNATORDISC W/FLANGE
TEMP SENSING ELEMENT TYPEINTERNAL SENSOR
TERMINAL TYPETAB, SOLDER LUG
TEST DATA DOCUMENT81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial