CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CONTACT SWITCHING ACTION | MAKES BEFORE BREAKS EACH SECTION FRONT |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CONTACT VOLTAGE RATING IN VOLTS | 200.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
DETENT ROTATIONAL TORQUE RANGE | +0.500 TO 6.000 INCH-POUNDS SINGLE ACTUATOR |
FIRST FLAT LENGTH | 0.400 INCHES MINIMUM AND 0.447 INCHES MAXIMUM SINGLE ACTUATOR |
FLAT HEIGHT | 0.216 INCHES NOMINAL SINGLE ACTUATOR |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND EXPLOSION PROOF |
INDIVIDUAL SECTION QUANTITY | 2 |
OVERALL DIAMETER | 1.950 INCHES MAXIMUM |
OVERALL LENGTH | 2.897 INCHES NOMINAL |
MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.469 INCHES SINGLE MOUNTING FACILITY |
NONTURN DEVICE TYPE | SLOTTED BUSHING AT 12:00 O'CLOCK |
OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
POLE QUANTITY | 1 EACH SECTION FRONT |
PRECIOUS MATERIAL AND LOCATION | CONTACTS AND TERMINAL SURFACES SILVER |
PRECIOUS MATERIAL | SILVER |
SHAFT DIAMETER | 0.247 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT LENGTH | 0.531 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT FLAT/SLOT ANGULAR LOCATION | 90.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR |
SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
SPECIFICATION/STANDARD DATA | 96906-MS21994 GOVERNMENT STANDARD |
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
SWITCH ACTUATOR POSITIONING INCREMENT | 45.0 DEGREES SINGLE ACTUATOR |
SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 4 SINGLE ACTUATOR |
TERMINAL TYPE | TAB W/SCREW |
TEST DATA DOCUMENT | 81349-MIL-S-6807 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.469 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNS SINGLE MOUNTING FACILITY |
THROW QUANTITY | 3 EACH SECTION FRONT |