CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL |
| 300.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| 115.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD AND |
| 50.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
| 250.0 MILLIAMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| 50.0 MILLIAMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
TERMINAL TYPE | TAB, SOLDER LUG |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 19 SINGLE ACTUATOR |
STYLE DESIGNATOR | CIRCULAR WAFER, BUSHING MOUNT |
OVERALL LENGTH | 5.750 INCHES NOMINAL |
OVERALL HEIGHT | 1.875 INCHES NOMINAL |
OVERALL WIDTH | 1.609 INCHES NOMINAL |
INDIVIDUAL SECTION QUANTITY | 10 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL AND |
| NONPILE-UP NONSYMMETRICAL |
POLE QUANTITY | 1 EACH SECTION FRONT |
THROW QUANTITY | 19 EACH SECTION FRONT |
CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES 2ND SECTION FRONT |
| BREAKS BEFORE MAKES 3RD SECTION FRONT |
| BREAKS BEFORE MAKES 4TH SECTION FRONT |
| BREAKS BEFORE MAKES 5TH SECTION FRONT |
| BREAKS BEFORE MAKES 6TH SECTION FRONT |
| BREAKS BEFORE MAKES 7TH SECTION FRONT |
| BREAKS BEFORE MAKES 8TH SECTION FRONT |
| BREAKS BEFORE MAKES 9TH SECTION FRONT |
| BREAKS BEFORE MAKES 10TH SECTION FRONT |
SWITCH ACTUATOR POSITIONING INCREMENT | 18.0 DEGREES SINGLE ACTUATOR |
SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
FIRST FLAT LENGTH | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
FLAT HEIGHT | 0.216 INCHES NOMINAL SINGLE ACTUATOR |
SHAFT DIAMETER | 0.247 INCHES MINIMUM AND |
| 0.250 INCHES MAXIMUM SINGLE ACTUATOR |
SHAFT LENGTH | 0.940 INCHES NOMINAL SINGLE ACTUATOR |
NONTURN DEVICE TYPE | TAB AT 3:00 O'CLOCK |
NONTURN DEVICE RADIUS | 0.531 INCHES NOMINAL AT 3:00 O'CLOCK |
MOUNTING METHOD | THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.374 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TEST DATA DOCUMENT | 81349-MIL-S-3786 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SHAFT FLAT/SLOT ANGULAR LOCATION | 0.0 DEGREES FROM CONTACT POSITION 1 SINGLE ACTUATOR |
OPERATING TEMP RANGE | -65.0 TO 85.0 DEG CELSIUS |