ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
BODY STYLE | SINGLE POLE TYPE |
BODY WIDTH | 1.875 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.063 INCHES NOMINAL |
CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.406 INCHES NOMINAL |
FRAGILITY FACTOR | MODERATELY RUGGED |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
OVERALL LENGTH | 3.227 INCHES NOMINAL |
MATERIAL | PLASTIC CASE |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 105.0 AMPERES DC SINGLE LOCATION |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 575.0 DC SINGLE LOCATION |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.625 INCHES MAXIMUM |
NOMINAL THREAD SIZE | 0.190 INCHES |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 28.0 DC SINGLE LOCATION |
POLE QUANTITY | 1 |
RESET METHOD | MANUAL |
SPECIFICATION/STANDARD DATA | 58536-AA55571/04-009 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
THREAD SERIES DESIGNATOR | UNF |
THREAD QUANTITY PER INCH | 32 |
TRIP RELEASE AMBIENT TEMP RATING | 25.0 CELSIUS NOMINAL SINGLE LOCATION |
TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 8.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
UNPACKAGED UNIT WEIGHT | 5.000 OUNCES NOMINAL |