5305-00-022-5628 SCREW,CAP,HEXAGON HEAD Index 5925-00-022-5631 CIRCUIT BREAKER

National Stock Number:
5925-00-022-5630

Federal Supply Class:
5925

National Item Identification Number:
000225630

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
1500-022-0576374SAFRAN ELECTRICAL & POWER USA, LLC
1500-022-0581640SAFRAN POWER USA, LLC
840019-0680249BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
POLE QUANTITY1
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 MILLIAMPERES AC AND
50.0 MILLIAMPERES DC SINGLE LOCATION
CIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
TERMINAL TYPE AND QUANTITY2 TAB W/SCREW
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC AND
30.0 DC SINGLE LOCATION
TRIP RELEASE CHARACTERISTICINSTANTANEOUS AND
TIME DELAY SINGLE LOCATION
RESET METHODMANUAL
BODY STYLESINGLE POLE TYPE
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING W/PANEL SEAL
CASE MATERIALPLASTIC
UNPACKAGED UNIT WEIGHT0.100 POUNDS NOMINAL
TRIP RELEASE METHODTHERMAL SINGLE LOCATION
FREQUENCY IN HERTZ400.0 SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS600.0 AC AND
6000.0 DC SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.380 MINIMUM AT 200 PCT AND
2.500 MAXIMUM AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0 SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
BUSHING LENGTH0.235 INCHES MINIMUM AND
0.265 INCHES MAXIMUM
BODY LENGTH1.122 INCHES MINIMUM AND
1.152 INCHES MAXIMUM
BODY WIDTH0.750 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.685 INCHES MINIMUM AND
0.715 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE1.843 INCHES MAXIMUM
THREAD SERIES DESIGNATORUNS
NOMINAL THREAD SIZE0.469 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDEXPLOSION PROOF
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
PRECIOUS MATERIALSILVER
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES SILVER
FRAGILITY FACTORMODERATELY RUGGED


Click here to Register for Free 30-day Trial