5950-00-504-8869 TRANSFORMER,POWER Index 5950-00-504-8878 COIL,RADIO FREQUENCY

National Stock Number:
5915-00-504-8870

Federal Supply Class:
5915

National Item Identification Number:
005048870

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
2762556289SPRAGUE ELECTRIC CO WORLD HQS
420-69-040382577RAYTHEON COMPANY
FA57513619EMS DEVELOPMENT CORPORATION
FA57581831FILTRON CO INC DIV OF RFI CORP
IN20870637ASSOCIATED VALVE AND ENGINEERING CO
NF1032500853CORNELL-DUBILIER MARKETING INC
NF1032514655CORNELL-DUBILIER ELECTRONICS


Techincal Specification:
BODY HEIGHT0.703 INCHES MAXIMUM
BODY LENGTH1.156 INCHES MAXIMUM
BODY WIDTH1.031 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.422 INCHES MINIMUM AND 1.454 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OUTPUT TERMINAL IDENTIFICATION1
OVERALL LENGTH1.906 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE1000.0 KILOVOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION500.0 MILLIVOLTS AC BLANK
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 BLANK
OPERATING TEMP RANGE-55.0 TO 100.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ1000.0 BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.141 INCHES NOMINAL