Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
337-465-900170210HONEYWELL INTERNATIONAL INC.
GF948807294GENISCO FILTER CORP
GF948813050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
NF2086493790CORNELL-DUBILIER ELECTRONICS, INC.


Techincal Specification:
BODY HEIGHT0.780 INCHES NOMINAL
BODY LENGTH1.180 INCHES MAXIMUM
BODY SURFACE TREATMENTTIN
BODY WIDTH1.060 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.452 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL HEIGHT0.780 INCHES MAXIMUM
OVERALL LENGTH1.750 INCHES MAXIMUM
OVERALL WIDTH1.380 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.5 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.5 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING TEMP RANGE-65.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION26.0 VOLTS AC 1ST RADIO INTERFERENCE AND 28.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION26.0 VOLTS AC 2ND RADIO INTERFERENCE AND 28.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.150 INCHES NOMINAL
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0