DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.000 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
BODY HEIGHT | 1.280 INCHES MAXIMUM |
BODY MATERIAL | METAL |
BODY LENGTH | 4.000 INCHES NOMINAL |
BODY SURFACE TREATMENT | TIN |
BODY WIDTH | 2.750 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD INPUT 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
INCLOSURE TYPE | HERMETICALLY SEALED |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
PROPRIETARY CHARACTERISTICS | PACS |
MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 1ST RADIO INTERFERENCE |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 3RD RADIO INTERFERENCE |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 2ND RADIO INTERFERENCE |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
NOMINAL THREAD SIZE | 0.164 INCHES |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 4.5 1ST RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 4.5 2ND RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 4.5 3RD RADIO INTERFERENCE |
OPERATING TEMP RANGE | -65.0/+85.0 DEG CELSIUS |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OVERALL LENGTH | 5.000 INCHES MAXIMUM |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
SPECIAL FEATURES | WIRE LEADS 9.000 IN. LONG MINIMUM |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
UNPACKAGED UNIT WEIGHT | 2.000 POUNDS |