3040-00-449-0728 SHAFT,STRAIGHT Index 5365-00-449-0738 SPACER,ROTOR

National Stock Number:
5915-00-449-0732

Federal Supply Class:
5915

National Item Identification Number:
004490732

Description:
FILTER,HIGH PASS-LOW PASS

Detail:
A SINGLE ITEM HAVING THE DUAL FUNCTION OF A FILTER, HIGH PASS AND A FILTER, LOW PASS. EACH FILTER MAY HAVE A SEPARATE INPUT CONNECTION, BUT EACH FILTER MUST HAVE SEPARATE OUTPUT CONNECTIONS. EXCLUDES A SINGLE INDUCTANCE, CAPACITANCE, OR RESISTOR. SEE FILTER, BAND SUPPRESSION.


Manufacturer Information:
945917857KARKAR ELECTRONICS INC


Techincal Specification:
BODY MATERIALMETAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM SINGLE HIGH PASS AND 60.0 MAXIMUM SINGLE HIGH PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM SINGLE LOW PASS AND 60.0 MAXIMUM SINGLE LOW PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.250 INCHES NOMINAL
FEATURES PROVIDEDMAGNETIC CASE AND MOISTURE RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION1.00 HERTZ SINGLE LOW PASS AND 12.30 KILOHERTZ SINGLE LOW PASS 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION11.70 KILOHERTZ SINGLE HIGH PASS AND 23.40 KILOHERTZ SINGLE HIGH PASS 1ST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 SINGLE HIGH PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 SINGLE LOW PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION75.0 OHMS SINGLE HIGH PASS 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION75.0 OHMS SINGLE LOW PASS 2ND FUNCTION
OVERALL HEIGHT6.000 INCHES NOMINAL
OVERALL LENGTH16.000 INCHES NOMINAL
OVERALL WIDTH2.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE SINGLE HIGH PASS 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE SINGLE LOW PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION11.7 KILOHERTZ SINGLE HIGH PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION12.3 KILOHERTZ SINGLE LOW PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION75.0 OHMS SINGLE HIGH PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION75.0 OHMS SINGLE LOW PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ SINGLE HIGH PASS AND 5.85 KILOHERTZ SINGLE HIGH PASS AND 11.70 KILOHERTZ SINGLE HIGH PASS AND 23.40 KILOHERTZ SINGLE HIGH PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ SINGLE LOW PASS AND 5.85 KILOHERTZ SINGLE LOW PASS AND 11.70 KILOHERTZ SINGLE LOW PASS AND 23.40 KILOHERTZ SINGLE LOW PASS 2ND FUNCTION
UNTHREADED MOUNTING HOLE DIAMETER0.156 INCHES NOMINAL


Click here to Register for Free 30-day Trial