5961-00-432-9264 SEMICONDUCTOR DEVICE,DIODE Index 5905-00-432-9267 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5915-00-432-9265

Federal Supply Class:
5915

National Item Identification Number:
004329265

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
0N16202998230NATIONAL SECURITY AGENCY
105-54555520QUALITY MAGNETICS INC
2-10131601G B INSTRUMENTS INC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT4.250 INCHES NOMINAL
BODY LENGTH3.062 INCHES NOMINAL
BODY WIDTH2.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.297 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.856 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL HEIGHT4.625 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE1.25 KILOVOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING TEMP RANGE-40.0 TO 105.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SPECIAL FEATURESTERMINAL 2 COMMON
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0