4820-00-126-4703 GUIDE,VALVE STEM Index 5915-00-126-4705 FILTER,BAND PASS

National Stock Number:
5915-00-126-4704

Federal Supply Class:
5915

National Item Identification Number:
001264704

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
37484-142498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
37484-1REVH42498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
BP118709376OMNITEC DATA CORP SUB OF NYTRONICS INC
F-11861L8V1MAGNETIKA INC
F-118653342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
76556662FREQUENCY SELECTIVE NETWORKS, INC.


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION155.0 KILOHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION155.00 KILOHERTZ BLANK AND
160.00 KILOHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE HOOK INPUT 1ST FUNCTION
1 PIN OUTPUT 2ND FUNCTION
2 PIN GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
INPUT IMPEDANCE PER FUNCTION W/LOAD5.0 KILOHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT25.0 KILOHMS BLANK
OVERALL HEIGHT2.594 INCHES MAXIMUM
BODY LENGTH4.000 INCHES MAXIMUM
BODY HEIGHT2.250 INCHES MAXIMUM
BODY WIDTH1.375 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED STUD 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.625 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION131.00 KILOHERTZ BLANK AND
155.00 KILOHERTZ BLANK AND
160.00 KILOHERTZ BLANK AND
177.00 KILOHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 NOMINAL BLANK AND
3.0 NOMINAL BLANK 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK
AVERAGE LIFE RATING IN HOURS10000.0
OPERATING TEMP RANGE0.0 TO 70.0 DEG CELSIUS


Click here to Register for Free 30-day Trial