5950-00-020-5795 TRANSFORMER,RADIO FREQUENCY Index 5915-00-020-5797 FILTER,BAND PASS

National Stock Number:
5915-00-020-5796

Federal Supply Class:
5915

National Item Identification Number:
000205796

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
0060629601217082679THE TECHNICAL MATERIAL CORPORATION
287TYPE8NS09747POWER CONTROL DEVICES INC
8NS28709747POWER CONTROL DEVICES INC
FX17682679THE TECHNICAL MATERIAL CORPORATION


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION250.0 KILOHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS11.0 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION249.95 KILOHERTZ BLANK AND
250.05 KILOHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION
1 PIN OUTPUT 2ND FUNCTION
2 PIN GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT8.2 KILOHMS BLANK
OVERALL HEIGHT2.375 INCHES NOMINAL
BODY LENGTH2.090 INCHES MINIMUM AND
3.010 INCHES MAXIMUM
BODY HEIGHT1.990 INCHES MINIMUM AND
2.010 INCHES MAXIMUM
BODY WIDTH1.395 INCHES MINIMUM AND
1.605 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.145 INCHES MINIMUM AND
2.355 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.395 INCHES MINIMUM AND
0.605 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION249.85 KILOHERTZ BLANK AND
249.95 KILOHERTZ BLANK AND
250.05 KILOHERTZ BLANK AND
250.10 KILOHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 NOMINAL BLANK AND
3.0 NOMINAL BLANK 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK
OPERATING TEMP RANGE-0.0 TO 70.0 DEG CELSIUS
BODY MATERIALMETAL