5910-00-539-7687 CAPACITOR,FIXED,ELECTROLYTIC Index 4470-00-539-7691 DRAWER ASSEMBLY

National Stock Number:
5910-00-539-7689

Federal Supply Class:
5910

National Item Identification Number:
005397689

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
023065-000065597THALES USA, INC.
05C0440G0297942NORTHROP GRUMMAN SYSTEMS CORPORATION
140-122752151CONTINENTAL ELECTRONICS CORP
2306565597THALES USA, INC.
270242-706668TEXAS INSTRUMENTS INC INFORMATION TECHNOLOGY GROUP
283745210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
283745282679THE TECHNICAL MATERIAL CORPORATION
335C758H0197942NORTHROP GRUMMAN SYSTEMS CORPORATION
6666202-08396296SOLAR MFG CORP
858S-100021052HIGH ENERGY CORP.
858S100071590CRL COMPONENTS INC
858S1000PF5KVDCW71590CRL COMPONENTS INC
A94881535AERONAUTICAL COMMUNICATIONS EQUIPMENT INC
DC8E102MA75255TLC FORESTRY, LLC
HH58T102MAB21052HIGH ENERGY CORP.
HH58T102ML21052HIGH ENERGY CORP.
X53696296SOLAR MFG CORP


Techincal Specification:
BODY DIAMETER0.812 INCHES MAXIMUM
BODY LENGTH0.625 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION1000.000 PICOFARADS SINGLE SECTION
INSULATION RESISTANCE AT REFERENCE TEMP10000.0 MEGOHMS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED MOUNTING HOLES
NOMINAL THREAD SIZE0.138 INCHES
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION5000.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
POWER FACTOR AT REFERENCE TEMP IN PERCENT1.5000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-1.0 TO 1.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
TERMINAL LENGTH0.133 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 THREADED STUD
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION