5910-00-506-6640 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-00-506-6643 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-00-506-6641

Federal Supply Class:
5910

National Item Identification Number:
005066641

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
102D144A156289SPRAGUE ELECTRIC CO WORLD HQS
110D286X0075M156289SPRAGUE ELECTRIC CO WORLD HQS
29F58324454GENERAL ELECTRIC CO ELECTRONIC COMPONENTS DIVISION OF ELECTRONIC ATOMIC AND DEFENSE SYSTEMS GROUP
29F583G424454GENERAL ELECTRIC CO ELECTRONIC COMPONENTS DIVISION OF ELECTRONIC ATOMIC AND DEFENSE SYSTEMS GROUP
29F583G495018GENERAL ELECTRIC CO TRANSFORMER DIVISION OF APPARATUS GROUP
M39006/03-141781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39006/381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
BODY DIAMETER0.406 INCHES MAXIMUM
BODY LENGTH2.203 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION28.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE INSULATION MATERIALPLASTIC
DC LEAKAGE AT REFERENCE TEMP4.000 MICROAMPERES
DC LEAKAGE AT MAXIMUM OPERATING TEMP26.0 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT10.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS80.0
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-3
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION75.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-39006/3 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39006 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial