5310-00-498-7635 NUT,SELF-LOCKING,PLATE Index 5950-00-498-7640 TRANSFORMER,POWER

National Stock Number:
5910-00-498-7637

Federal Supply Class:
5910

National Item Identification Number:
004987637

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
10105-21M35S27914HONEYWELL INTERNATIONAL INC DBA HONEYWELL
10215-003027914HONEYWELL INTERNATIONAL INC DBA HONEYWELL
K10J35S05397UNION CARBIDE CORP MATERIALS SYSTEMS DIV
2088355-3027914HONEYWELL INTERNATIONAL INC DBA HONEYWELL
195-010-912170210HONEYWELL INTERNATIONAL INC.
40657-7999167HAMILTON SUNDSTRAND CORPORATION
SCM106GP035D401295TEXAS INSTRUMENTS INCORPORATED
TAS107M035P1G90201MALLORY SONALERT PRODUCTS, INC.


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.289 INCHES NOMINAL
BODY LENGTH0.686 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION10.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE INSULATION MATERIALPLASTIC
DC LEAKAGE AT MAXIMUM OPERATING TEMP13.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP1.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT6.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-80.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT40657-99167 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial