2590-00-473-5701 COVER,CONTROL BOX Index 4920-00-473-5703 INTERCONNECTION DEV

National Stock Number:
5910-00-473-5702

Federal Supply Class:
5910

National Item Identification Number:
004735702

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
B95001A0094B100C0426HENSOLDT SENSORS GMBH
CS13BF106M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M26655-2-018281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC26655-281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.274 INCHES MINIMUM AND 0.305 INCHES MAXIMUM
BODY LENGTH0.822 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION10.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
DC LEAKAGE AT MAXIMUM OPERATING TEMP50.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP4.000 MILLIAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT6.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-26655/2 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION