5910-00-465-9755 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5910-00-465-9757 CAPACITOR,FIXED,GLASS DIELECTRIC

National Stock Number:
5910-00-465-9756

Federal Supply Class:
5910

National Item Identification Number:
004659756

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
352250011175H0203THALES NEDERLAND B.V.
5M.5271.222.77D1901HENSOLDT SENSORS GMBH
CE71C152F81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC62-1281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CE71C152F99392MEPCO/ELECTRA INC ROXBORO DIV


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPEPLAIN FOIL
BODY DIAMETER1.437 INCHES NOMINAL
BODY LENGTH2.500 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE END
CAPACITANCE VALUE PER SECTION1500.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALALUMINUM
CASE INSULATION MATERIALPLASTIC
DC LEAKAGE AT REFERENCE TEMP291.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT40.0000
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS16.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION25.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-40.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY2 THREADED HOLE
TEST DATA DOCUMENT81349-MIL-C-62+12 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 75.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial