5935-00-520-4813 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5998-00-520-4818 CIRCUIT CARD ASSEMBLY

National Stock Number:
5905-00-520-4816

Federal Supply Class:
5905

National Item Identification Number:
005204816

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
579R713H0197942NORTHROP GRUMMAN SYSTEMS CORPORATION
GB41J2015801HONEYWELL INTERNATIONAL INC.
TX18481L9U5MEASUREMENT SPECIALTIES, INC.
TX184883186MEAS US LLC DIV TEMPERATURE PRODUCTS GROUP DBA MEASUREMENT SPECIALTIES


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER125.0 CELSIUS
BODY LENGTH0.090 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.045 INCHES NOMINAL
INCLOSURE TYPEENCASED
MAXIMUM CURRENT RATING25.00 AMPERES
MAXIMUM POWER DISSIPATION RATING1.00 WATTS
MAXIMUM OPERATING TEMP300.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS0.4
REFERENCE TEMP IN DEG CELSIUS25.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.5 TO 10.5 4TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.5 TO 12.5 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.3 TO 13.3 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.6 TO 15.6 6TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.3 TO 16.3 2ND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.5 TO 17.5 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-19.2 TO 19.2 8TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.9 TO 20.9 1ST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-22.4 TO 22.4 9TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-24.5 TO 24.5 10TH RESISTANCE-TEMPERATURE POINT
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.2 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP126.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP124.8 OHMS 9TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.9 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE10.000 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-3.90
ZERO POWER RESISTANCE AT SPECIFIED TEMP28.5 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP294.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP38.4 OHMS 10TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP565.5 OHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP760.8 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP8.3 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORSEALED OR COATED BEAD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-30.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-60.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER120.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER200.0 CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER30.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER300.0 CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER60.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER90.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TERMINAL LENGTH0.200 INCHES NOMINAL
TERMINAL DIAMETER0.004 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS4.0