5905-00-517-6849 RESISTOR,FIXED,WIRE WOUND,NONIND Index 5995-00-517-6851 CABLE ASSEMBLY,RADIO FREQUENCY

National Stock Number:
5905-00-517-6850

Federal Supply Class:
5905

National Item Identification Number:
005176850

Description:
RESISTOR,FIXED,FILM

Detail:
A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of either a thin layer of conductive material, containing either binders or insulating materials, deposited on an insulated form; or an alloy of metal and ceramic materials, usually fused to an insulated form. Opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the resistor. See also ATTENUATOR, FIXED and RESISTOR, FIXED, COMPOSITION. Excludes carbon composition type resistors.


Manufacturer Information:
443-1851-19894756THE BOEING COMPANY
94416-562106481NORTHROP GRUMMAN SYSTEMS CORPORATION
C3-1/8-T0-5621-G24546DALE ELECTRONICS INC A VISHAY INTERTECHOLOGY INC CO P O BOX 74 NORFOLK NE68702-0074
ERC50-7-19891637VISHAY DALE ELECTRONICS, LLC
MIL-PRF-55182/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-55182/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RNC50J5621FS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE5.620 KILOHMS
AMBIENT TEMP AT FULL RATED POWER125.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER175.0
BODY DIAMETER0.065 INCHES NOMINAL
BODY LENGTH0.150 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORC
POWER DISSIPATION RATING IN WATTS0.050 FREE AIR
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RELIABILITY INDICATORESTABLISHED
SPECIFICATION/STANDARD DATA81349-MIL-R-55182/7 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 175.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-25.0 TO 25.0
TERMINAL LENGTH1.250 INCHES NOMINAL
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-55182 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
UNPACKAGED UNIT WEIGHT0.110 GRAMS


Click here to Register for Free 30-day Trial