5950-00-497-9055 TRANSFORMER,POWER Index 5999-00-497-9057 MOUNTING PAD,ELECTRICAL-ELECTRON

National Stock Number:
5905-00-497-9056

Federal Supply Class:
5905

National Item Identification Number:
004979056

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
3020209150AMPEX DATA SYSTEMS CORP COMPUTER PRODUCTS DIV
3020209214GENERAL ELECTRIC CO SEMI-CONDUCTOR PRODUCTS DEPT POWER COMPONENTS OPN
3D20250157THERM-O-DISC INC SUB OF EMERSON ELECTRIC CO


Techincal Specification:
BODY OUTSIDE DIAMETER0.200 INCHES NOMINAL
BODY WIDTH0.084 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS8.0
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.8 OHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP85.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP9.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE30.000 OHMS
ZERO POWER RESISTANCE AT SPECIFIED TEMP20.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORBEAD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-50.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS28.0