AMBIENT TEMP AT FULL RATED POWER | 100.0 CELSIUS |
BODY LENGTH | 0.350 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.105 INCHES MAXIMUM |
INCLOSURE TYPE | HERMETICALLY SEALED |
MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
MAXIMUM POWER DISSIPATION RATING | 2.50 MILLIWATTS |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
STYLE DESIGNATOR | ROD |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 103.6 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 114.9 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 30.8 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 34.2 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 37.1 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 88.5 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
ZERO POWER RESISTANCE | 56.000 OHMS |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -35.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -65.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 130.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
TERMINAL LENGTH | 1.200 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
THERMAL TIME CONSTANT IN SECONDS | 60.0 |