ZERO POWER RESISTANCE | 3.500 OHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
INCLOSURE TYPE | ENCASED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | ROD |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 22.0 |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 8.0 |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -1.40 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| -20.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| -10.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 12.9 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 8.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 10.1 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| 2.4 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| 1.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| 1.2 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
BODY LENGTH | 0.375 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.220 INCHES MAXIMUM |
TERMINAL LENGTH | 1.125 INCHES MINIMUM |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 96774 |
MFR SOURCE CONTROLLING REFERENCE | 534-1001-04 |