5915-00-424-9601 FILTER,RADIO FREQUENCY INTERFERE Index 5961-00-424-9604 TRANSISTOR

National Stock Number:
5905-00-424-9603

Federal Supply Class:
5905

National Item Identification Number:
004249603

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
05C0659G0197942NORTHROP GRUMMAN SYSTEMS CORPORATION
41A2-10PCT1L9U5MEASUREMENT SPECIALTIES, INC.
41A2-10PCT83186MEAS US LLC DIV TEMPERATURE PRODUCTS GROUP DBA MEASUREMENT SPECIALTIES


Techincal Specification:
ZERO POWER RESISTANCE10.000 KILOHMS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
INCLOSURE TYPEENCAPSULATED
RELIABILITY INDICATORNOT ESTABLISHED
STYLE DESIGNATORSEALED OR COATED BEAD
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
AMBIENT TEMP AT FULL RATED POWER25.0 DEG CELSIUS
MAXIMUM OPERATING TEMP300.0 DEG CELSIUS
THERMAL TIME CONSTANT IN SECONDS2.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS0.7
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-4.40
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-40.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
-25.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
200.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
300.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP350.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
130.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
3.5 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
700.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT
65.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT
15.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS
BODY OUTSIDE DIAMETER0.043 INCHES NOMINAL
TERMINAL LENGTH0.312 INCHES NOMINAL
TERMINAL DIAMETER0.004 INCHES NOMINAL
TEST DATA DOCUMENT81349-MILT23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).