Search Criteria

NSN/NIIN No.:
Part No. :
(13-16 digit NSN/9 digit NIIN)
5945-00-543-83085945-00-543-8306
NSNDescriptionAssign Date
5945-00-543-8307RELAY,ELECTROMAGNETIC01/01/1961
NSNDescriptionDetailOpen Solicitations
5945-00-543-8307RELAY,ELECTROMAGNETIC0
Part NumberCompanyCAGE
80K850514GENERAL DYNAMICS MISSION SYSTEMS, INC.1VPW8
80K850514MOTOROLA INC. DBA INTEGRATED INFORMATION SYSTEMS G94990
59B81111GENERAL DYNAMICS MISSION SYSTEMS, INC.1VPW8
For additional information Register for Free Trial
NameValue
WINDING QUANTITY1
COIL QUANTITY1
WINDING DC RESISTANCE RATING19.8 OHMS NOMINAL SINGLE WINDING
PILE-UP MAIN CONTACT FORM ARRANGEMENT2A
NOMINAL OPERATING CURRENT RATING AND TYPE120.0 MILLIAMPERES DC SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND
10.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND
28.0 DC
For additional information Register for Free Trial
CodeDefinition
ACQUISITION METHOD CODE.
'All Departments3ACQUIRE DIRECTLY FROM THE ACTUAL MANUFACTURER, WHETHER OR NOT THE PRIME CONTRACTOR IS THE ACTUAL MANUFACTURER.
ACQUISITION METHOD SUFFIX CODE.
'All DepartmentsHTHE GOVERNMENT PHYSICALLY DOES NOT HAVE IN ITS POSSESSION SUFFICIENT, ACCURATE, OR LEGIBLE DATA TO PURCHASE THIS PART FROM OTHER THAN CURRENT SOURCE(S). (NOTE: THIS CODE IS APPLICABLE ONLY TO PARTS UNDER IMMEDIATE BUY REQUIREMENTS AND ONLY AS LONG AS THE DEFICIENCY IS UNDER REVIEW FOR RESOLUTION AND APPROPRIATE RECODING.) VALID AMCS: 1, 2, 3, 4 AND 5.
MAJOR ORGANIZATIONAL ENTITY.
NavyDNNavy
Defense Logistics Agency.DSDefense Logistics Agency.
PRICE
All DepartmentsPrice15.73
PRECIOUS METALS INDICATOR CODES.
All DepartmentsUPrecious Metal type is unknown.
CRITICALITY CODE.
All DepartmentsXThe item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
AUTOMATIC DATA PROCESSING EQUIPMENT.
All Departments
ELECTROSTATIC DISCHARGE CODE.
All Departments
HAZARDOUS MATERIALS INDICATOR CODE.
All DepartmentsNIndicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
DEMILITARIZATION CODE.
All DepartmentsANo-USML/Non-CCLI – No DEMIL or DoD TSC required. Department of Commerce may impose licensing requirements to certain destinations. (Note 9).
For additional information Register for Free Trial
ITEM NAME RELAY,ARMATURE NO DATA IS AVAILABLE. THE ALTERNATE OFFEROR IS REQUIRED TO PROVIDE A COMPLETE DATA PACKAGE INCLUDING DATA FOR THE APPROVED AND ALTERNATE PART FOR EVALUATION.
Cage# 1VPW8 and PartNumber# 80K850514
Cage# 94990 and PartNumber# 80K850514