Search Criteria

NSN/NIIN No.:
Part No. :
(13-16 digit NSN/9 digit NIIN)
5915-00-009-24765910-00-009-2474
NSNDescriptionAssign Date
5915-00-009-2475FILTER,RADIO FREQUENCY INTERFERE07/29/1972
NSNDescriptionDetailOpen Solicitations
5915-00-009-2475FILTER,RADIO FREQUENCY INTERFERE0
Part NumberDescriptionCompanyQuantity
GF55922FILTER COMPONENT ENTERPRISES COMPANY, INC.0
FILTER,RADIO FREQUENCY INTERFERE RELLI TECHNOLOGY (ISRAEL) LTD.0
For additional information Register for Free Trial
CompanyAward DateQuantityPriceContractDelivery Date
Free Trial07/20/2003Free TrialFree TrialSP090503VB569
Free Trial07/07/1994Free TrialFree TrialSP090594MB664
Free Trial07/05/1989Free TrialFree TrialDLA90089MKM30
Free Trial07/01/1989Free TrialFree TrialDLA90089MKM30
Free Trial05/30/1985Free TrialFree TrialDLA90085MJZ30
Free Trial02/01/1984Free TrialFree TrialDLA90084MT915
Free Trial12/01/1982Free TrialFree TrialDLA90083MK384
For additional information Register for Free Trial
Part NumberCompanyCAGE
GF55922GENISCO FILTER CORP07294
GF55922SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/13050
865089-10NORTHROP GRUMMAN SYSTEMS CORPORATION06481
865089-10LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISIO13973
For additional information Register for Free Trial
NameValue
BODY LENGTH8.500 INCHES NOMINAL
BODY WIDTH6.000 INCHES NOMINAL
BODY HEIGHT3.000 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH12.875 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH5.562 INCHES NOMINAL
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END3.500 INCHES NOMINAL
INCLOSURE TYPEHERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT AND 4 TURRET INPUT AND 2 TURRET GROUND
For additional information Register for Free Trial
CodeDefinition
ACQUISITION METHOD CODE.
'All Departments3ACQUIRE DIRECTLY FROM THE ACTUAL MANUFACTURER, WHETHER OR NOT THE PRIME CONTRACTOR IS THE ACTUAL MANUFACTURER.
ACQUISITION METHOD SUFFIX CODE.
'All DepartmentsCTHIS PART REQUIRES ENGINEERING SOURCE APPROVAL BY THE DESIGN CONTROL ACTIVITY IN ORDER TO MAINTAIN THE QUALITY OF THE PART. AN ALTERNATE SOURCE MUST QUALIFY IN ACCORDANCE WITH THE DESIGN CONTROL ACTIVITY’S PROCEDURES, AS APPROVED BY THE COGNIZANT GOVERNMENT ENGINEERING ACTIVITY. VALID AMCS: 1, 2, 3, 4 AND 5.
MAJOR ORGANIZATIONAL ENTITY.
NavyDNNavy
Defense Logistics Agency.DSDefense Logistics Agency.
PRICE
All DepartmentsPrice1875.97
PRECIOUS METALS INDICATOR CODES.
All DepartmentsUPrecious Metal type is unknown.
CRITICALITY CODE.
All DepartmentsXThe item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
AUTOMATIC DATA PROCESSING EQUIPMENT.
All Departments
ELECTROSTATIC DISCHARGE CODE.
All Departments
HAZARDOUS MATERIALS INDICATOR CODE.
All DepartmentsPIndicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
DEMILITARIZATION CODE.
All DepartmentsDUSML Items – DEMIL required. Destroy item and components to prevent restoration or repair to a usable condition. (Note 5).
For additional information Register for Free Trial
FILTER,RADIO FREQUENCY IF THE APPLICABLE (OEM OR MILITARY) DRAWING, SPECIFICATION, STANDARD, OR QUALITY ASSURANCE PROVISION (QAP) SPECIFIES AN ACCEPTABLE QUALITY LEVEL (AQL), THE SAMPLING ACCEPTANCE NUMBER SHALL BE REDUCED TO ZERO (0). FOR EXAMPLE, IF THE ACCEPT REJECT CRITERIA IS ACCEPT ON (3) DEFECTS AND REJECT ON (4) DEFECTS, THE NEW ACCEPT REJECT CRITERIA IS ACCEPT ON (0) DEFECTS AND REJECT THE ENTIRE LOT ON (1) DEFECT. EVEN THOUGH THE ACCEPTANCE LEVEL IS ELIMINATED, THE SAMPLE SIZE REMAINS THE SAME. ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE OFFERS IS NOT AVAILABLE AT THE PROCUREMENT AGENCY. THE OFFEROR MUST PROVIDE A COMPLETE DATA PACKAGE INCLUDING DATA FOR THE APPROVED AND ALTERNATE PART FOR EVALUATION.